Acetabulum Cup Alignment with and Without Guide in Total Hip Replacement
DOI:
https://doi.org/10.70749/ijbr.v3i4.2020Keywords:
Acetabular cup alignment, total hip replacement, mechanical guide, safe zone, freehand technique, hip arthroplasty, Department of Orthopedics, CMH Rawalpindi, PakistanAbstract
Introduction: Successful total hip replacement (THR) depends on the precise concentricity of acetabular cups. Malposition may cause dislocation, impingement, early loosening, and revision surgery. In the resource-constrained environment, the accuracy of alignment becomes difficult to achieve, particularly using the freehand technique. Alignment guide use can be a potentially inexpensive solution to improve accuracy and reduce complications. Objective: To compare the accuracy of acetabular cup placement in total hip arthroplasty with and without the use of mechanical alignment guides at Department of Orthopedics, CMH Rawalpindi, Pakistan. Material and Method: This comparative prospective study involved 60 participants and conducted at Department of Orthopedics, CMH Rawalpindi, Pakistan, who underwent unilateral primary THR from August, 2024 to January, 2025. The patients were split into two groups. Group A (n=30) was operated under guided cup insertion, and Group B (n=30) under freehand insertion. The radiographs taken after the surgery were measured using inclination and anteversion angles, and the placement was assessed according to the safe zone of Lewinnek angles. Results: Guide-assisted placement led to much better alignment. The average inclination angle and anteversion angle in Group A were 42.6 degrees +/-4.3 degrees and 17.1 degrees +/-3.9 degrees, respectively, as compared to Group B, whose average was 47.3 degrees +/-6.1 degrees and 22.8 degrees +/-5.4 degrees, respectively (p<0.01). The compliance with the safe zone was 86.7 per cent in Group A as compared to 56.7 percent in Group B (p=0.009). There was a slight difference in operative time in Group A, which was not significant. Conclusion: The probability of being ascribed to predicting acetabular cup placement using alignment guides in THR significantly increases. Simple guide systems may be incorporated into working practice in low-resource environments, where they could improve surgical accuracy and decrease the likelihood of postoperative complications.
Downloads
References
1. Kohno Y, Nakamura T, Fujii M, Shin S, Hara T. A laser guide technique: a novel method for accurate acetabular cup alignment in total hip arthroplasty. Scientific Reports. 2022 Oct 29;12(1):18247.
https://doi.org/10.1038/s41598-022-21975-x
2. Meermans G, Grammatopoulos G, Innmann M, Beverland D. Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics. EFORT open Reviews. 2022 Jun 1;7(6):365-74.
https://doi.org/10.1530/eor-22-0025
3. Sai Sathikumar A, Jacob G, Thomas AB, Varghese J, Menon V. Acetabular cup positioning in primary routine total hip arthroplasty—a review of current concepts and technologies. Arthroplasty. 2023 Dec 1;5(1):59.
https://doi.org/10.1186/s42836-023-00213-3
4. Xu J, Veltman ES, Chai Y, Walter WL. Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty. SICOT-J. 2023 May 5;9:12.
https://doi.org/10.1051/sicotj/2023010
5. Streck LE, Boettner F. Achieving precise cup positioning in direct anterior total hip arthroplasty: a narrative review. Medicina. 2023 Jan 31;59(2):271.
https://doi.org/10.3390/medicina59020271
6. Pongkunakorn A, Wongkamthong N, Ruktrakul R. Cup positioning relative to the acetabular rim planned with three-dimensional computed tomography improves precision in total hip arthroplasty: a randomized controlled trial. Journal of Orthopaedic Surgery and Research. 2025 Mar 27;20(1):318.
https://doi.org/10.1186/s13018-025-05704-4
7. Bruce-Brand R, Magill P, O’Neill C, Karayiannis P, Hill J, Beverland D. Mechanical and anatomical alignment guide techniques are superior to freehand in achieving target orientation of an acetabular component. Arthroplasty Today. 2021 Oct 1;11:222-8.
https://doi.org/10.1016/j.artd.2021.08.016
8. Naito Y, Hasegawa M, Tone S, Wakabayashi H, Sudo A. The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system. BMC Musculoskeletal Disorders. 2021 Dec 4;22(1):1016.
https://doi.org/10.1186/s12891-021-04902-5
9. Patamarat A, Laoruengthana A, Kitcharanant N, Khantasit J, Thremthakanpon W. Direct anatomic registration in computer-assisted total hip arthroplasty improves accuracy of acetabular cup alignment. Arthroplasty Today. 2023 Jun 1;21:101148.
https://doi.org/10.1016/j.artd.2023.101148
10. Vasiljeva K, Lunn D, Chapman G, Redmond A, Wang L, Thompson J, Williams S, Wilcox R, Jones A. Dynamic Acetabular Cup Orientation during Gait: A Study of Fast-and Slow-Walking Total Hip Replacement Patients. Bioengineering. 2024 Feb 2;11(2):151.
https://doi.org/10.3390/bioengineering11020151
11. Hayashi S, Hashimoto S, Kuroda Y, Nakano N, Matsumoto T, Ishida K, Shibanuma N, Kamenaga T, Kuroda R. Accuracy of cup position following robot-assisted total hip arthroplasty may be associated with surgical approach and pelvic tilt. Scientific Reports. 2021 Apr 7;11(1):7578.
https://doi.org/10.1038/s41598-021-86849-0
12. Crone TP, Cornelissen BM, Van Oldenrijk J, Bos PK, Veltman ES. Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review. World Journal of Orthopedics. 2024 Jul 18;15(7):660.
https://doi.org/10.5312/wjo.v15.i7.660
13. Tsukamoto M, Kawasaki M, Suzuki H, Fujitani T, Sakai A. Proposal of accurate cup placement procedure during total hip arthroplasty based on pelvic tilt discrepancies in the lateral position. Scientific Reports. 2021 Jul 6;11(1):13870.
https://doi.org/10.1038/s41598-021-93418-y
14. Harada S, Hamai S, Motomura G, Ikemura S, Fujii M, Kawahara S, Sato T, Hara D, Nakashima Y. Evaluation of optimal implant alignment in total hip arthroplasty based on postoperative range of motion simulation. Clinical Biomechanics. 2022 Feb 1;92:105555.
https://doi.org/10.1016/j.clinbiomech.2021.105555
15. Nemati HM, Christensson A, Pettersson A, Németh G, Flivik G. Precision of cup positioning using a novel computed tomography based navigation system in total hip arthroplasty. Medicina. 2024 Sep 27;60(10):1589.
https://doi.org/10.3390/medicina60101589
16. Nakasone S, Takaesu M, Ishihara M, Onaga M, Igei T, Miyata Y, Nishida K. Accuracy of acetabular cup placement during total hip arthroplasty in supine position using a pelvic rotation correction device. Arthroplasty Today. 2022 Aug 1;16:46-52.
https://doi.org/10.1016/j.artd.2022.04.004
17. Ferretti A, Iannotti F, Proietti L, Massafra C, Speranza A, Laghi A, Iorio R. The accuracy of patient-specific instrumentation with laser guidance in a dynamic total hip arthroplasty: a radiological evaluation. Sensors. 2021 Jun 20;21(12):4232.
https://doi.org/10.3390/s21124232
18. Meermans G, Fawley D, Zagra L, Ten Broeke RH, Johnson K, Bernard T, Thomason III HC. Accuracy of cup placement compared with preoperative surgeon targets in primary total hip arthroplasty using standard instrumentation and techniques: a global, multicenter study. Journal of Orthopaedics and Traumatology. 2024 May 10;25(1):25.
https://doi.org/10.1186/s10195-024-00766-2
19. Mouri K, Madachi A, Karita T. Intraoperative pelvic tilt and axial rotation during total hip arthroplasty through the direct anterior approach is affected by the acetabular retractor and cup impactor. Arthroplasty Today. 2023 Dec 1;24:101251.
https://doi.org/10.1016/j.artd.2023.101251
20. Ruhr M, Baetz J, Pueschel K, Morlock MM. Influence of acetabular cup thickness on seating and primary stability in total hip arthroplasty. Journal of Orthopaedic Research®. 2022 Sep;40(9):2139-46.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Indus Journal of Bioscience Research

This work is licensed under a Creative Commons Attribution 4.0 International License.