To Evaluate the Outcome of 3-D Titanium Plates versus Conventional Miniplates in the Management of Mandibular Angle Fracture in Abbasi Shaheed Hospital

Authors

  • Samreen Naeem Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.
  • Zahid Ali Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.
  • Hafza Mashama Yaqoob Patel Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.
  • Asar Fatima Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.
  • Amna Zubair Ghazi Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.
  • Tayyaba Khurshid Department of Oral and Maxillofacial Surgery, Abbasi Shaheed Hospital, Karachi, Sindh, Pakistan.

DOI:

https://doi.org/10.70749/ijbr.v3i7.2185

Keywords:

3-D Titanium Plates, Conventional Miniplates, Mandibular Angle Fracture, Surgical Management

Abstract

Objective: To evaluate and compare the clinical outcomes of three-dimensional (3D) titanium plates versus conventional miniplates in the surgical management of mandibular angle fractures. Methods: This randomized controlled trial was conducted in the Department of Oral and Maxillofacial Surgery at Abbasi Shaheed Hospital, Karachi in the duration from 11th January, 2025 to 15th June, 2025. A total of 60 adult patients with closed unilateral mandibular angle fractures were randomly assigned into two groups: Group 1 (3D plates, n=30) and Group 2 (conventional miniplates, n=30). Outcome measures included operative time, pain scores, postoperative mouth opening, and infection rates. Surgeries were performed under general anesthesia by a single surgeon using a standardized approach. Data were analyzed using SPSS v23, with independent t-tests and Chi-square tests applied. Results: Group 1 had significantly shorter operative times (44.0 ± 1.4 min vs. 54.5 ± 1.7 min; p < 0.001) and lower pain scores on both postoperative day 1 and day 7 (p < 0.001). Mouth opening on day 7 was clinically adequate in both groups, though slightly higher in the conventional group. Infection occurred in 6.7% of 3D plate patients and 16.7% in the conventional group (p = 0.42). No reoperations or hardware failures were reported. Conclusion: 3D titanium plates provide efficient, stable fixation for mandibular angle fractures, with reduced operative time and postoperative discomfort. Their use is supported by both clinical performance and alignment with international evidence, making them a viable alternative to conventional miniplates in appropriate surgical settings.

Downloads

Download data is not yet available.

References

1. Tucker, D. I., Zachar, M. R., Chan, R. K., & Hale, R. G. (2013). Characterization and management of mandibular fractures. Atlas of the Oral and Maxillofacial Surgery Clinics, 21(1), 61-68.

https://doi.org/10.1016/j.cxom.2012.12.003

2. Allareddy, V., Allareddy, V., & Nalliah, R. P. (2011). Epidemiology of facial fracture injuries. Journal of Oral and Maxillofacial Surgery, 69(10), 2613-2618.

https://doi.org/10.1016/j.joms.2011.02.057

3. Haug, R. H., Prather, J., & Thomas Indresano, A. (1990). An epidemiologic survey of facial fractures and concomitant injuries. Journal of Oral and Maxillofacial Surgery, 48(9), 926-932.

https://doi.org/10.1016/0278-2391(90)90004-l

4. Ellis Iii, E. (1999). Treatment methods for fractures of the mandibular angle. International Journal of Oral and Maxillofacial Surgery, 28(4), 243-252.

https://doi.org/10.1034/j.1399-0020.1999.284280401.x

5. Wagner, W. F., Neal, D. C., & Alpert, B. (1979). Morbidity associated with extraoral open reduction of mandibular fractures. Journal of Oral Surgery (American Dental Association: 1965), 37(2), 97-100.

https://europepmc.org/article/med/283211

6. Feller, K., Schneider, M., Hlawitschka, M., Pfeifer, G., Lauer, G., & Eckelt, U. (2003). Analysis of complications in fractures of the mandibular angle—a study with finite element computation and evaluation of data of 277 patients. Journal of Cranio-Maxillofacial Surgery, 31(5), 290-295.

https://doi.org/10.1016/s1010-5182(03)00015-5

7. Balakrishnan, R., Ebenezer, V., & Dakir, A. (2014). Three dimensional titanium mini plates in management of mandibular fractures. Biomedical & Pharmacology Journal, 7(1), 241-246.

https://doi.org/10.13005/bpj/480

8. Hochuli-Vieira, E., Ha, T. K., Pereira-Filho, V. A., & Landes, C. A. (2011). Use of rectangular grid Miniplates for fracture fixation at the mandibular angle. Journal of Oral and Maxillofacial Surgery, 69(5), 1436-1441.

https://doi.org/10.1016/j.joms.2010.06.182

9. An, W., Ainiwaer, A., Wusiman, P., Ali, G., & Moming, A. (2018). Surgical management of mandibular angle fractures. Journal of Craniofacial Surgery, 29(7), 1702-1708.

https://doi.org/10.1097/scs.0000000000004568

10. Mishra, N., Thakkar, N., Kar, I., Baig, S. A., Sharma, G., Kar, R., Sahu, G. R., & Birmiwal, K. G. (2017). 3-D Miniplates versus conventional Miniplates in treatment of mandible fractures. Journal of Maxillofacial and Oral Surgery, 18(1), 65-72.

https://doi.org/10.1007/s12663-017-1068-x

11. El Nakeeb, N. A., El Dibany, M. M., & Shokry, M. M. (2016). A comparative study between 3-d plates and conventional miniplates for internal fixation of anterior mandibular fractures. Alexandria Dental Journal, 41(3), 253-260.

https://doi.org/10.21608/adjalexu.2016.58036

12. Pir, U., Khattak, H. B., Muhammad Sohail, Shah, S. A., Khan, A., Zaman, R., Khan, S., & Saifullah. (2024). Comparison of 3-d and standard miniplates fixation in the management of angle fracture of the mandible. JOURNAL OF KHYBER COLLEGE OF DENTISTRY, 14(2), 11-15.

https://doi.org/10.33279/jkcd.v14i2.180

13. Yatindra, I. A. C. D., & Samsarga, G. W. (2024). The comparison of three-dimensional plate versus standard plate in the management of mandible fracture: A meta-analysis and systematic review of randomized controlled trials. Neurologico Spinale Medico Chirurgico, 7(2), 77-88.

https://doi.org/10.4103/nsmc.nsmc_13_24

14. Hassnain, T. U., Hussain, U., Abbas, W., Khan, M. A., Khan, M. A., & Hashmi, M. J. (2022). Comparison of outcome of conventional Miniplates versus 3-D Miniplates for reduction of mandibular fractures. Pakistan Journal of Medical and Health Sciences, 16(4), 967-969.

https://doi.org/10.53350/pjmhs22164967

15. Pfister, J., Shazwani, F. N., Müller, M., & Burkhard, J. (2024). Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: A retrospective analysis. Oral and Maxillofacial Surgery, 28(4), 1501-1507.

https://doi.org/10.1007/s10006-024-01275-6

16. Pir, U., Khattak, H. B., Muhammad Sohail, Shah, S. A., Khan, A., Zaman, R., Khan, S., & Saifullah. (2024). Comparison of 3-d and standard miniplates fixation in the management of angle fracture of the mandible. JOURNAL OF KHYBER COLLEGE OF DENTISTRY, 14(2), 11-15.

https://doi.org/10.33279/jkcd.v14i2.180

Downloads

Published

2025-07-15

How to Cite

Naeem, S., Ali, Z., Yaqoob Patel, H. M. ., Fatima, A., Ghazi, A. Z., & Khurshid, T. (2025). To Evaluate the Outcome of 3-D Titanium Plates versus Conventional Miniplates in the Management of Mandibular Angle Fracture in Abbasi Shaheed Hospital. Indus Journal of Bioscience Research, 3(7), 834-837. https://doi.org/10.70749/ijbr.v3i7.2185