Comparison of Open Reduction and Internal Fixation with PHILOS Plate versus Close Reduction and Fixation with Percutaneous K-wiring in Proximal Humerus Fractures

Authors

  • Muhammad Sadam Habib Department of Orthopedic, Allama Iqbal Teaching Hospital DG Khan, Punjab, Pakistan.
  • Ishrat Nazir Department of Orthopedic, Allama Iqbal Teaching Hospital DG Khan, Punjab, Pakistan.
  • Syed Habibullah Shah Department of Orthopedic, Allama Iqbal Teaching Hospital DG Khan, Punjab, Pakistan.
  • Zubair Kareem Department of Orthopedic, Allama Iqbal Teaching Hospital DG Khan, Punjab, Pakistan.
  • Shafqat Hussain Department of Orthopedic, Allama Iqbal Teaching Hospital DG Khan, Punjab, Pakistan.
  • Nida Akram Central Park Medical College, Lahore, Punjab, Pakistan.

DOI:

https://doi.org/10.70749/ijbr.v3i4.2017

Keywords:

Proximal Humerus Fracture, PHILOS Plate, K-wire Fixation, Neer Score, Functional Outcome, Shoulder Surgery

Abstract

Introduction: Fractures of the proximal humerus are the most common injuries in the upper limbs, especially in the elderly. Surgical options are available, including open reduction and PHILOS plating, as well as K-wire percutaneously reduced fixation, each with its advantages and disadvantages. Objectives: The study aims to discuss the clinical and functional outcomes of plate fixation using the PHILOS plate compared to K-wire fixation of proximal humerus fractures. Materials and Methods: This was a randomised controlled trial involving 144 patients treated at the Department of Orthopaedics, Allama Iqbal Teaching Hospital, DG Khan, between February 2024 to November 2024. The patients were separated into two categories, Group A (plating using PHILOS) and Group B (K-wire fixation). The result was evaluated using Neer's scoring system after 12 weeks. Results: Group A rated significantly higher in functional outcome, with 48.6% achieving an excellent outcome, compared to 27.8% in Group B. Complication rates were low in the PHILOS group. Conclusion: PHILOS plating represents a better functional outcome and fewer complications than the K-wire in the fixation of the proximal humerus fractures in the displaced proximal humerus fractures.

Downloads

Download data is not yet available.

References

1. Sata, V. R., Vadera, U. R., Parmar, D. S., & Dodia, A. V. (2021). A study on outcome of surgical neck humerus fractures managed operatively by proximal humerus interlocking (PHILOS) plate. International Journal of Science and Research (IJSR), 10(1), 1-4.

https://doi.org/10.21275/sr201228220221

2. Raithatha, H., Patil, V. S., Pai, M., & Shah, S. (2023). Clinical and radiological outcome of dual plating for proximal humerus fractures. Cureus.

https://doi.org/10.7759/cureus.33570

3. Kakati, A., Garg, S., Rath, R., Meena, L. N., & Maharia, R. (2022). Management of proximal humerus fracture in adults with philos plate fixation in Neer type 2 and type 3. Asian Journal of Pharmaceutical and Clinical Research, 148-151.

https://doi.org/10.22159/ajpcr.2022.v15i10.46417

4. Desai, S. S., Shah, R. V., & Chudasama, V. D. (2025). Functional and radiological outcomes of percutaneous wiring for two and three part fractures of the proximal humerus. Journal of Clinical Orthopaedics and Trauma, 67, 103044.

https://doi.org/10.1016/j.jcot.2025.103044

5. Buchmann, L., Van Lieshout, E. M., Zeelenberg, M., Den Hartog, D., Pfeifer, R., Allemann, F., Pape, H., & Halvachizadeh, S. (2021). Proximal humerus fractures (PHFs): Comparison of functional outcome 1 year after minimally invasive plate osteosynthesis (MIPO) versus open reduction internal fixation (ORIF). European Journal of Trauma and Emergency Surgery, 48(6), 4553-4558.

https://doi.org/10.1007/s00068-021-01733-w

6. Tecimel, O. (2021). The comparison of single plate and double plate fixation methods for treatment of humeral shaft nonunions. Joint Diseases and Related Surgery, 32(1), 67-74.

https://doi.org/10.5606/ehc.2021.74488

7. Patel, Y. C., Majumdar, S., Shah, S., Lathiya, H., & Bhadani, A. (2023). “Study of outcome of proximal humerus fracture treated with proximal humerus internal locking system (Philos) plating”. International Journal of Orthopaedics Sciences, 9(2), 117-126.

https://doi.org/10.22271/ortho.2023.v9.i2b.3359

8. Birajdar, A. (2024). A comparative analysis of functional recovery after Philos plating versus J-nail for proximal humerus fractures. African Journal of Biomedical Research, 3353-3360.

https://doi.org/10.53555/ajbr.v27i3s.2933

9. Reddy, P. A., Krishna, K. S., & Priyanka, N. (2025). A Retrospective Comparative Study of Surgical Management of 4 Part Proximal Humerus Fractures between Internal Fixation with Philos Plate and Hemi Replacement with Neers Prosthesis. International Journal of Pharmacy Research & Technology (IJPRT), 15(1), 152-154.

https://www.ijprt.org/index.php/pub/article/view/338

10. Liu, J., Zhang, Z., Li, P., & Piao, C. (2024). Enhancing fixation stability in proximal humerus fractures: Screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing. Scientific Reports, 14(1).

https://doi.org/10.1038/s41598-024-78702-x

11. Tammam, H. A., Said, E., Hamed, H., & Khairy, A. (2024). Evaluation of surgical treatment by PHILOS plate versus conservative treatment for displaced proximal humeral fractures in elderly patients. SVU-International Journal of Medical Sciences, 7(2), 556-568.

https://doi.org/10.21608/svuijm.2024.255695.1761

12. Yun, C., Qian, W., Zhang, J., Zhang, W., & Lv, J. (2023). Biomechanics of PHILOS plates in Vancouver B1 periprosthetic femoral fracture. Frontiers in Bioengineering and Biotechnology, 11.

https://doi.org/10.3389/fbioe.2023.1282128

13. Agrawal, U., & Narayandas, D. K. (2024). Assessment of functional outcome and postoperative complications in proximal humerus fracture patients managed with proximal humerus internal locking system (PHILOS) plating. Cureus.

https://doi.org/10.7759/cureus.63250

14. El-Geoshy, A. M., Abdalla, U. G., & Gaafar, E. K. (2024). PHILOS plating versus percutaneous K-wire fixation in proximal humerus fractures in the elderly. Al-Azhar International Medical Journal, 5(2).

https://doi.org/10.58675/2682-339x.2270

15. Le, J., Lu, J., Zhang, J., Wu, Z., & Chen, L. (2025). Comparison of the clinical outcomes and radiological parameters between the greater tuberosity strengthened proximal humeral plate and the proximal humeral internal locking system plate in the minimally invasive plate osteosynthesis treatment of proximal humeral fractures involving the greater tuberosity: A retrospective cohort study. BMC Musculoskeletal Disorders, 26(1).

https://doi.org/10.1186/s12891-025-08543-w

16. Saito, T., Matsumura, T., Sasanuma, H., Iijima, Y., & Takeshita, K. (2021). PHILOS plating of periprosthetic humeral shaft fracture after onlay-type reverse total shoulder arthroplasty: A case report. JSES Reviews, Reports, and Techniques, 1(1), 65-68.

https://doi.org/10.1016/j.xrrt.2020.11.003

17. Bhakare, A., Pundkar, G., Baitule, R., Jaiswal, S., Kharat, S., & Rokade, A. (2023). Randomized clinical trial to assess functional outcome and complication of surgical neck humerus fracture (Two part and three part) treated by percutaneous K-wire fixation and Philos plating. Journal of Orthopaedic Diseases and Traumatology, 6(2), 142-148.

https://doi.org/10.4103/jodp.jodp_76_22

18. Suroto, H., De Vega, B., Deapsari, F., Prajasari, T., Wibowo, P. A., & Samijo, S. K. (2021). Reverse total shoulder arthroplasty (RTSA) versus open reduction and internal fixation (ORIF) for displaced three-part or four-part proximal humeral fractures: A systematic review and meta-analysis. EFORT Open Reviews, 6(10), 941-955.

https://doi.org/10.1302/2058-5241.6.210049

19. Liu, Q., Cao, Z., Liu, J., Liu, Z., & Zhang, W. (2025). Comparison of the efficacy of Philos plate and Multiloc intramedullary nail in the treatment of complex proximal humeral fractures with osteoporosis in the elderly. Frontiers in Surgery, 12.

https://doi.org/10.3389/fsurg.2025.1606898

Downloads

Published

2025-04-30

How to Cite

Comparison of Open Reduction and Internal Fixation with PHILOS Plate versus Close Reduction and Fixation with Percutaneous K-wiring in Proximal Humerus Fractures. (2025). Indus Journal of Bioscience Research, 3(4), 889-893. https://doi.org/10.70749/ijbr.v3i4.2017